Danfoss MCO 305 Design Manual page 77

Programmable motion controller
Hide thumbs Also See for MCO 305:
Table of Contents

Advertisement

MCO 305 Design Guide
Parameter
The → Parameter function will reset all global and axis parameters in the controller to their initialization
values.
Arrays
The → Arrays function will delete all arrays in RAM. This function has the same effect as the DELETE
ARRAYS command.
NB!:
Note that if Memory → Save RAM is subsequently used, or an APOSS program executes the SAVE
ARRAYS command, then the arrays in the EPROM are also deleted!
Complete
The → Complete function will reset all parameters and delete all arrays and programs. The MCO 305 Option
is reset to the original factory setting.
NB!:
Reset → Complete happens immediately. This differs from Memory → Delete EPROM which
happens only after the controller has been turned off and on again.
Arrays, User Parameters, All App.data
Use the corresponding function to reset → Arrays, → User Parameters or → All Application data (which also
contains the application program in addition to the user parameters and arrays) individually in the LCP-
EEPROM. The reset is executed at once!
Error History
Click on Controller → Error History to see a history of all the errors that have occurred on the controller.
NB!:
Some older versions of controller do not support this function. The function will be disabled in this
case.
Errors are listed from most recent at the top of the list to oldest at the bottom of the list. The list is cleared
each time that the controller is powered on. The list holds a maximum of 50 errors; the oldest error will be
discarded when a new error is added to the list.
__ PC Software Interface __
®
MG.33.L5.02 – VLT
is a registered Danfoss trademark
77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents