MCO 305 Design Guide
__ APOSS Tools __
The white boxes in the "Status" column indicate that controllers are not connected. However, the controller
ID and connection interface can be seen at the far right side of the "Curve Selection List".
When Oscilloscope files are opened, controllers are never connected automatically. This allows Oscilloscope
files to be opened and analyzed offline. Controllers can be reconnected either using the toolbar buttons or
using the right mouse button in the "Curve Selection List" (see Status Column in "Curve Selection List").
Usage Notes for the Single Shot Oscilloscope
When the Single Shot Oscilloscope starts, it will
automatically add a single group in the same way
that the Free Run Oscilloscope does. However, the
user is required to specify some characteristics of
the TESTSETP array that will be used to record the
curve data. The following window will be displayed:
Recording Method
For the Single Shot Oscilloscope, the recording method must be Single Shot.
Storage Location
This specifies the location where the TESTSETP array will be stored. If set the Dynamic Memory, then the
TESTSETP array will be placed in available free memory in the controller. Note that the amount of free
memory will depend on the size and number of programs and other data already stored in the controller. If
set to Array, then the TESTSETP array will be placed in the specified user-defined array in the controller.
This array must already have been defined by the user's application program.
Storage Mode
This determines what happens when the TESTSETP array becomes full. If it is set to Cyclic, then new data
will start to overwrite old data and the old data will be lost. If set to Stop when full, then recording stops
once the TESTSETP array is full and new data will be lost.