Danfoss MCO 305 Design Manual page 100

Programmable motion controller
Hide thumbs Also See for MCO 305:
Table of Contents

Advertisement

MCO 305 Design Guide
__ APOSS Tools __
Curve profile settings
The Settings section of the CAM-Editor Window
contains checkboxes for displaying and hiding
various attributes of the curve profile diagram.
Velocity
Display the velocity curve corresponding to the curve profile. This is displayed as a blue line. The grid scale
for this curve is displayed down the right side of the curve profile diagram (as long as this is the only grid to
be displayed on the right side of the chart).
Vel. Limit
Display the velocity limits as two horizontal dark blue lines.
Acceleration
Display the acceleration curve corresponding to the curve profile. This is displayed as a magenta line. The
grid scale for this curve is displayed down the right side of the curve profile diagram (as long as this is the
only grid to be displayed on the right side of the chart).
Acc. Limit
Display the acceleration limits as two horizontal dark magenta lines.
Jerk
Display the "jerk" curve corresponding to the curve profile. The "jerk" is the impulse on the drive as a result
of acceleration changes. This is displayed as a cyan (light blue) line. The grid scale for this curve is dis-
played down the right side of the curve profile diagram (as long as this is the only grid to be displayed on
the right side of the chart).
Slave Stop
Display the slave stop position (defined in the Curve Data index card) as a horizontal grey bar.
Start-Stop
Display the positions of the Start Stop points as yellow or red flags on the curve profile.
Engage Path
Display the engage path for the currently selected Start Stop pair. This is displayed as a dark blue curve
from the slave stop position to the curve profile between the Start Stop pair.
Note that a Start Stop pair must be selected in the Start Stop Points table before anything is displayed.
Disengage Path
Display the disengage path for the currently selected Start Stop pair. This is also displayed as a dark blue
curve.
Master Marker
Display the master marker position (derived from the data in the Curve Data, Synchronization, and Sync
Marker index cards). This is displayed as a vertical green line. If a tolerance has been specified, then the
tolerance area is displayed as a pale green rectangle underneath the master marker position.
Slave Marker
Display the slave marker position (derived from the data in the Curve Data, Synchronization, and Sync
Marker index cards). This is displayed as a horizontal green line. If a tolerance has been specified, then the
tolerance area is displayed as a pale green rectangle underneath the slave marker position.
100
®