MAP 0200: 055 AFTA errors

Symptom explanation
055 MACHINE CHECK
The AFTA sensor circuit did not detect that needle 5B moved at the
correct time during the AFTA routine. The needle either failed to
extend or was not detected when it was pushed back.
!
CAUTION:
The printhead may be hot. Wait for it to cool down.
Table 10. MAP 0200: 55 AFTA errors
Step
Questions/Actions
Perform the Standard AFTA Service Check (see Print Head
1.
Gap Service Checks).
Is the service check OK?
Suspected FRUs/causes
Printhead misaligned and loosely fastened
AFTA motor defective
26-conductor printhead cable damaged or poor connection
Mechanical parts damaged or binding
Printhead defective
Engine board defective
Yes
Go to step 2.
No
Repair as needed.
Mount forms, and try loading
and parking forms several
times.
Run T&D in automatic test
mode to verify correct printer
operation (see Running the
test and diagnostic (T&D)
programs).