Press the SET TOP OF FORM key to enter. Threshold values written in NVRAM display. If both tractors are
installed, threshold values written in NVRAM display.)
REAR
:
FRONT
:
where:
v X1 is the threshold for the rear (default) path
v X2 is the threshold for the front (second or optional) path
v X1, X2 are numbers in hexadecimal format, which correspond to the measured voltages, resolution of 20
mV.
If the optional second tractor is not installed, threshold values written in NVRAM display:
T&D SENSORS TEST
FRONT
:
where:
v x1 is the threshold for the front (default) tractor
v x1 is a number in hexadecimal format, which correspond to the measured voltages, resolution of 20 mV.
Press any key to go to step 7.
7. The following displays:
T&D18 SENSORS TEST
SENS. LEV.
This part of the test is intended for use by Product Engineering, and allows the user to examine sensor output
voltages.
8. Press the LOAD/EJECT key to skip to step 9 on page 111.
Press the SET TOP OF FORM key to enter.
X1
X2
PRESS A KEY
X1
PRESS A KEY
YES
NO
110
Chapter 2. Diagnostics