InfoPrint 4247 Z03 Maintenance Information page 89

Hide thumbs Also See for 4247 Z03:
Table of Contents

Advertisement

Note: T&D06 and T&D07 require the use of parallel and serial loop-back connectors respectively.
3. Hold the TEST and SCROLL/MICRO ↓ keys at the same time.
4. Power on the printer.
5. When the display is:
RELEASE KEYS
Release the TEST and SCROLL/MICRO ↓ keys.
6. The following message will be displayed.
TEST & DIAGNOSTIC START UP
SINGLE
7. To run all the tests sequentially, go to Automatic Test Mode step 9 on page 90.
To run specific tests, go to the Single Test Mode in the next step.
8. Single Test Mode:
Note: If you are running T&Ds in single test mode, you can only increment forward (by pressing
LOAD/EJECT) through the tests. T&D tests increment forward in a continuous loop giving you access
to any T&D through a series of LOAD/EJECT key presses.
TEST & DIAGNOSTIC START UP
SINGLE
a. Press the SET TOP OF FORM key to select YES (run single test mode). The following message will be
displayed:
T&DXX Test
Description
RUN TEST?
b. To scroll to the desired test, press the LOAD/EJECT (NO) key.
c. To run the currently displayed test, press the SET TOP OF FORM (YES) key.
For a description of each test, go to Test Descriptions or return to the step that sent you here.
d. If the test is completed successfully, the present test description is displayed again.
YES
YES
YES
NO
NO
NO
89
Chapter 2. Diagnostics