T&D17-Top Cover Interlock Test - InfoPrint 4247 Z03 Maintenance Information

Hide thumbs Also See for 4247 Z03:
Table of Contents

Advertisement

The print test will print, and the display will be:
T&D14 FANFOLD FORM PRINT
TEST RUNNING
5. When the print test is complete, the following message is displayed:
T&D14 FANFOLD FORM PRINT
TEAR
&
PRESS KEY
6. Tear off the single page printout, and press any key.
7. For printout analysis, see Print quality service checks.
8. If an error message is displayed, go to T&D error messages and actions.
9. The test completed successfully if the present test is displayed again. Press the LOAD/EJECT key to
skip to the next test.
T&D17—Top cover interlock test
Ensure the top cover interlock magnet is properly installed.
The display shows:
T&D17 TOP COVER TEST
RUN TEST?
1. Press the SET TOP OF FORM to execute test.
It the top cover is open (or if the interlock magnet is not present) when this tests starts, the display shows:
T&D17 TOP COVER TEST
CLOSE COVER
2.
Close the cover (or properly install the interlock magnet) within 10 seconds, or an error message is
generated. If an error message is generated, press LOAD/EJECT to resume test.
3. Press SET TOP OF FORM to execute the test. Press LOAD/EJECT to skip to the next test.
YES
NO
107