Ribbon Lift Motor - InfoPrint 4247 Z03 Maintenance Information

Hide thumbs Also See for 4247 Z03:
Table of Contents

Advertisement

Ribbon lift motor

CAUTION:
<2-25> High temperature; switch off the printer and allow at least 20 minutes for parts in this area to cool before
handling.
Ribbon Lift
Motor Screws

Ribbon Lift Motor

Connector
Printhead
Printhead
Cable
1. Turn off the printer and disconnect the power cord from the
rear of the printer.
2. Open the top cover and remove the ribbon.
Attention:
In the next step, use care not to pull the wires out of
the ribbon lift connector.
3. Remove the 2 ribbon lift motor screws, and then disconnect
the connector from the printhead circuit card.
Installation notes
1. Carefully route the cable around the platen side of the motor
between the mounting post and the motor.
Chapter 5. Removals, service checks and adjustments