If both tractors are installed, the current sensor measurements display:
REAR
:
FRONT
:
where:
v x1 is rear (base) path measurement
v x2 is front (second or optional) path measurement
v x1, x2 are numbers in hexadecimal format, which correspond to the measured voltages, resolution of 20
mV.
The display continuously updates to track sensor output changes.
If the optional second tractor is not installed, the current sensor measurements display:
T&D SENSORS TEST
FRONT
:
where:
v x1 is rear tractor path measurement rear tractor.
v x1 is a number in hexadecimal format, which correspond to the measured voltages, resolution of 20 mV.
The display continuously updates to track sensor output changes.
Press any key to go to step 9.
9. The following displays:
T&D18 SENSORS TEST
REP. TEST
Press the SET TOP OF FORM key to restart from path status, step 2 on page 108.
Press the LOAD/EJECT key to end the test.
The present test will be displayed again. Press the LOAD/EJECT key again to return to "T&D13—Tear-off line
adjustment test" on page 103.
X1
X2
PRESS A KEY
X1
PRESS A KEY
YES
NO
111
Chapter 2. Diagnostics