Ground Connectors Check - InfoPrint 4247 Z03 Maintenance Information

Hide thumbs Also See for 4247 Z03:
Table of Contents

Advertisement

Check safety documentation for the correct test equipment and procedures before performing any of the following
|
tasks:
|
v Checking ac voltage at all associated power receptacles
|
v Checking that all associated power receptacles are properly grounded
|
DANGER
<1-10> Hazardous voltages are present. Do not touch the pins or sockets of the power receptacle.
Use only the applicable high-voltage probes. 4247 Model Z03 nominal ac input power requirements gives the
|
appropriate voltage ranges.
|
The printer electrical outlet and any temporary power tap, must meet the requirements as stated in 4247 Model
Z03 nominal ac input power requirements.
Attention:
If the voltages are not within the correct operating range, allow correction before the equipment is
plugged in and operated.
For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible.
4247 Model Z03 nominal ac input power requirements
Nominal Voltage
100–230 V ac

Ground connectors check

Using Figure 1 on page 18 and Figure 2 on page 19, ensure that all safety grounds are correctly installed.
Voltage Range
90–264 V ac
Amps
2.9–1.3 A
Single phase / 50–60 Hz
Phase / Hz
17
Safety inspection