T&D10-Afta Calibrate Test - InfoPrint 4247 Z03 Maintenance Information

Hide thumbs Also See for 4247 Z03:
Table of Contents

Advertisement

4. When the sensors are tuned, You will be prompted to the "RIBBON RUN" test. The following message
will display:
T&D09 SENSOR TUNE/RIBBON
TO RUN
5. Press SET TOP OF FORM to execute ribbon test. Visually inspect for correct ribbon movement. Press
LOAD/EJECT to stop ribbon movement.
6. The ribbon feed and the ribbon lift motors run continuously during this test. This feeds the ribbon, and
raises and lowers the ribbon lift. You must press the LOAD/EJECT key to stop the test. If either motor
fails, go to MAP 0160: Ribbon feed and ribbon lift.
7. If an error message is displayed, go to T&D error messages and actions.
8. The test completed successfully if the present test is displayed again. Press LOAD/EJECT to skip to
the next test.
T&D10—AFTA calibrate test
You must complete this test to:
v Calibrate the microcode for the printhead
- and -
v Adjust the gap between the printhead needles and the platen
Note: Do not run T&D10 unless instructed to do so by the "Print Head Gap Service Checks" on page 142 or the
"Automatic Forms Thickness Adjustment (AFTA)" on page 138.
Display:
T&D10 AFTA CALIBRATE
RUN TEST?
Press SET TOP OF FORM to execute test. Press LOAD/EJECT to skip test.
If any error messages display during this test, go to T&D error messages and actions.
PRESS
YES
NO
96
Chapter 2. Diagnostics

Advertisement

Table of Contents
loading