Press LOAD/EJECT to move the paper down, or SET TOP OF THE FORM to move the paper up until the red dot
painted on the left end of the platen shaft is aligned with the white dot on the left bearing. This is the position of
the maximum platen eccentricity (minimum gap) where the calibration of the microcode should be made. If the
platen assembly does not have a painted red dot, the procedure must be repeated at least 3 times on different
points along the diameter of the platen. Select the point where the AFTA marker has the minimum value and paint
a red dot on the left end of the platen shaft for later use.
Press CANCEL PRINT to execute AFTA.
Display:
T&D10 AFTA CALIBRATE
STORE
Press LOAD/EJECT to change the AFTA calibrate value.
Press SET TOP OF THE FORM to store the AFTA calibrate value which completes the test.
To change the AFTA calibrate value if NO is selected:
Display:
T&D10 AFTA CALIBRATE
AFTA (n)
+
Press LOAD/EJECT to decrease the AFTA value.
Press SET TOP OF THE FORM to increase the AFTA value.
Press CANCEL PRINT to execute AFTA using the displayed AFTA(n) value.
YES
NO
RUN
99
Chapter 2. Diagnostics