Reference for Environmental
Requirements
The operating and non-operating environmental requirements for the system are
as follows.
Parameter
Operating
Temperature
Humidity
Altitude
Vibration:
Deskside
Rackmounted
Shock:
Deskside
Rackmounted
Declared Acoustics
Non-Operating
Temperature
Humidity
Altitude
Vibration:
Deskside
Rackmounted
Shock:
Deskside
Rackmounted
Handling Drops
Threshold Impact
Value
5˚C to 35˚C (41˚F to 95˚F)—IEC 68-2-1, 68-2-2
20% to 80% RH, noncondensing; 27 ˚C max wet bulb—IEC 68-2-2,
68-2-3
0 to 3000 meters (0 to 10,000 feet)—IEC 68-2-40, 68-2-41
2
0.0002 g
/Hz, 5 to 500 Hz (random)—IEC 68-2-6
2
0.00015 g
/Hz, 5 to 500 Hz (random)—IEC 68-2-6
4 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27
3 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27
6.7 bels dB(A) operating, 7.6 bels dB(A) at ok prompt
-20˚C to 60˚C (-4˚F to 140˚F)—IEC 68-2-1, 68-2-2
95% RH, noncondensing at 40˚C—IEC 68-2-2, 68-2-3
0 to 12,000 meters (0 to 40,000 feet)—IEC 68-2-40, 68-2-41
2
0.002 g
/Hz, 5 to 500 Hz (random)—IEC 68-2-6
2
0.0015 g
/Hz, 5 to 500 Hz (random)—IEC 68-2-6
15 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27e
10 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27e
50 mm—IEC 68-2-31
1 m/s—SUN 900-1813