15. Verify that the Solaris software recognizes all disks attached to each backplane.
Type the luxadm display command and specify the enclosure name for each
backplane.
In the following example, the base backplane (FCloop in the example) has six
attached disks in slots 0 through 5.
# luxadm display FCloop
SUNWGS INT FCBPL
DISK STATUS
SLOT
0
1
2
3
4
5
6
7
8
9
10
11
SUBSYSTEM STATUS
FW Revision:922A
Node WWN:508002000017c4d8
SSC100's - 0=Base Bkpln, 1=Base LoopB, 2=Exp Bkpln, 3=Exp LoopB
280
Sun Fire V890 Server Service Manual • October 2005
DISKS
On (O.K.)
On (O.K.)
On (O.K.)
On (O.K.)
On (O.K.)
On (O.K.)
On (Login failed)
On (Login failed)
On (Login failed)
On (Login failed)
On (Login failed)
On (Login failed)
Box ID:0
SSC100 #0:
O.K.(922A/ 8D3C)
SSC100 #1:
O.K.(922A/ 8D3C)
SSC100 #2:
Not Installed
SSC100 #3:
Not Installed
Temperature Sensors - 0 Base, 1 Expansion
0:22ºC
1Not Installed
(Node WWN)
20000004cf627ba1
20000004cf620dc0
20000020372aef55
20000004cf620a05
20000020372af169
20000004cf620c63
Enclosure Name:FCloop