2. Remove the two No. 2 Phillips screws and the three No. 1 Phillips screws securing
the system status assembly to the front of the system.
Take care not to damage the flex circuit.
3. Carefully remove the status assembly from the front of the system.
The status assembly is held in place by tabs on the left side and right top of the
assembly.
4. Disconnect the system status cable (P31) from the connector on the status
assembly.
5. Place the status assembly on an antistatic mat.
Chapter 5 Removing and Installing Miscellaneous Assemblies
Cable
165