What To Do - Sun Microsystems Fire V890 Service Manual

Hide thumbs Also See for Fire V890:
Table of Contents

Advertisement

What to Do

1. Remove the lower I/O fan tray bracket.
a. Disconnect the fan status cable (P27) from the back of the I/O fan flex circuit.
b. Remove the two Phillips screws securing the lower I/O fan tray bracket to the
centerplane.
c. Rotate the lower I/O fan tray bracket out from the system.
d. Place the bracket on an antistatic mat.
2. Disconnect the following cables from each backplane installed:
For cable connector locations, see
a. Base/expansion cable and/or base backplane power cable from the backplane at
connectors J0100 and J0801
2
b. I
C cable (P19) from the backplane at connector J0800
c. If a Sun StorEdge PCI Dual Fibre Channel Host Adapter card is connected to
the base backplane, the FC-AL data cables from the base backplane at
connectors C(J01100) and D(J01101)
184
Sun Fire V890 Server Service Manual • October 2005
"Cable Connector Locations" on page
212.