Reference for Physical Specifications
The dimensions and weight of the system are as follows.
Measurement
Height (with casters)
Width
Depth
Weight:
Minimum
Maximum
Power Cord
Reference for Electrical Specifications
The following table provides the electrical specifications for the system.
Parameter
Input
Nominal Frequencies
Nominal Voltage Range
Maximum Current AC RMS
AC Operating Range
Output
+3.3 VDC
+5 VDC
+12 VDC
+48 VDC
Maximum DC Power Output
Maximum System AC Power Consumption
Maximum System Heat Dissipation
Volt-Ampere Rating
304
Sun Fire V890 Server Service Manual • October 2005
U.S.
Metric
28.1 in.
71.4 cm
18.9 in.
48.0 cm
32.9 in.
83.6 cm
194.0 lb
88.0 kg
288.0 lb
130.6 kg
8.2 ft
2.5 m
Value
50 Hz or 60 Hz nominal
Autoranging 200 to 240 VAC
8 A @ 200 VAC (each power cord for two
power supplies per system)
180 to 264 Vrms, 47 - 63Hz
3 to 72 A
3 to 56 A
1 to 35 A
0 to 50 A
2509 Watts
3200 Watts
10,912 BTU/hr
2078 VA with 1629 Watt load (PF=0.98)
Comments
Actual weight depends on the
installed options