Sun Microsystems Fire V890 Service Manual page 316

Hide thumbs Also See for Fire V890:
Table of Contents

Advertisement

/pci@8,700000/pci@4/SUNW,qlc@4
LiD HA LUN
1
0
2
6
3
4
5
11. Perform a reconfiguration boot of the Solaris software. At the ok prompt, type the
boot -r command.
ok boot -r
12. Verify that the Solaris software recognizes both the base and expansion
backplanes. At the Solaris prompt, type the luxadm probe command.
# luxadm probe
Found Enclosure(s):
SUNWGS INT FCBPL
Logical Path:/dev/es/ses0
Logical Path:/dev/es/ses1
SUNWGS INT FCBPL
Logical Path:/dev/es/ses2
Logical Path:/dev/es/ses3
The luxadm probe command displays the enclosure name, World Wide Number,
and logical path name for each FC-AL backplane. Notice that the display shows the
same enclosure name (FCloop in the example) for both backplanes. Also note the
logical path name of each device. You need this information to perform
288
Sun Fire V890 Server Service Manual • October 2005
--- Port WWN ---
1
0
22000004cfce7fd3
0
0
22000004cfce8257
2
0
22000004cf837f8d
6
0
508002000019737a
3
0
22000004cfce7fb7
4
0
2200002037b3f76c
5
0
2200002037e7efec
Name:FCloop
Name:FCloop
----- Disk description -----
SEAGATE ST336752FSUN36G 0408
SEAGATE ST336752FSUN36G 0408
SEAGATE ST336605FSUN36G 0438
SUNW
SUNWGS INT FCBPL922A
SEAGATE ST336752FSUN36G 0408
SEAGATE ST336704FSUN36G 0726
SEAGATE ST336704FSUN36G 0726
Node WWN:5080020000197378
Node WWN:5080020000197548
Step
13.

Advertisement

Table of Contents
loading

Table of Contents