The system controller card plugs in to a dedicated slot on the system I/O board and
provides the following ports through an opening in the system rear panel:
10-Mbps Ethernet port via an RJ-45 twisted-pair Ethernet (TPE) connector
EIA-232D serial port via an RJ-45 connector
The two system controller ports can be used simultaneously.
Note – You must install the Solaris Operating System and the Sun Remote System
Control software prior to setting up an RSC console. For more information, refer to
the Sun Fire V890 Server Owner's Guide.
Once you install the operating system and the RSC software, you can then configure
the system to use RSC as the system console. For detailed instructions, refer to the
Sun Fire V890 Server Owner's Guide.

Configuration Rules

You can install the system controller card into a dedicated slot at the base of the
system I/O board. Never move the system controller card to another system slot, as
it is not a PCI-compatible card.
Note – The system controller card is not a hot-pluggable component. Before
installing or removing a system controller card, you must power off the system and
disconnect all system power cords.
Caution – All internal options (except disk drives and power supplies) must be
installed only by qualified service personnel.
230
Sun Fire V890 Server Service Manual • October 2005