Sun Microsystems Fire V890 Service Manual page 222

Hide thumbs Also See for Fire V890:
Table of Contents

Advertisement

8. On the CPU side of the system, fully tighten the six Phillips screws that secure the
disk cage to the chassis.
9. Tighten the two captive screws that secure the lower section of the disk cage to the
chassis.
The captive screws are accessed from two cutouts in the chassis, under the mounting
point for the CPU fan tray guide.
10. Connect the following cables to the base backplane:
For cable connector locations, see
a. Base backplane power cable (P16) to the base backplane at connector J0100
The cable is connected to the power distribution board at connector P15/J8.
2
b. I
C cable (P19) to the base backplane at connector J0800
c. If a Sun StorEdge PCI Dual Fibre Channel Host Adapter card is installed to
control Loop B of the FC-AL disk backplane, the card's FC-AL data cable to the
base backplane at connectors C(J01100) and D(J01101)
11. If the expansion FC-AL disk backplane is installed, connect the following cables:
a. Base/expansion cable (P2 and P43) to the expansion backplane at connectors
J0801 and J0100
194
Sun Fire V890 Server Service Manual • October 2005
"Cable Connector Locations" on page
212.