17) Open the upper right cover, and mount the face cover (small, large).
18) Close the upper right cover.
If condensation is found on the outside or inside of the machine at this point,
stop the work and wait unit the machine becomes fully used to the room
temperature. Resume the work after making sure that the machine is free of
condensation.
2.2.4 Mounting the Scanner System
iR7105 / iR7095 / iR7086
1) Open the ADF.
Remove the copyboard glass protective pad and tape.
2) Remove the scanner system fixing screw [1].
(Store the screw away for possible relocation of the machine in the
future.)
[1]
2.2.5 Mounting the Fixing Assembly
iR7105 / iR7095 / iR7086 / iR7095P
1) Open the front cover.
2) Shift the fixing transport assembly release lever [1] in the direction of the
arrow to unlock the transfer/separation charging assembly.
[1]
[1]
[2]
F-2-34
F-2-35
F-2-36
3) Slide out the fixing transport unit [1] to the front.
4) Remove the tape [1]; then, remove the tag [2] of the fixing transport as-
sembly and the separation release member [3].
Remove all foreign matter (e.g., glue from tape) from the transport belt.
0010-8943
5) Remove the tape used to keep the tag in place, and open the delivery as-
sembly [1]; then, remove the 2 fixing nip release screws [2] from the front
and the rear.
[1]
0010-8944
6) Close the delivery assembly.
2.2.6 Mounting the Charging Assembly
iR7105 / iR7095 / iR7086
1) Remove the transfer separation charging assembly front cover [1].
- screw [2]
[1]
F-2-37
[3]
[1]
[2]
F-2-38
[2]
F-2-39
Chapter 2
0010-8947
2-15