Chapter 2
- 2 screws (TP; M3X6) [1]
- 2 Cover rubber (for M3)
[1]
[2]
28) Hook the claw [1] of the rear upper right cover on the hole of the cover
support plate; then, fit the rear upper right cover [2] in place.
- 3 screws [3] (removed in step 1))
- screw (included; binding; M4X10) [4]
[2]
[3]

2.2.11 Mounting the Control Panel

iR7095P
1) Remove the upper rear right cover [1].
- 3 screws [2]
[1]
[2]
2) Match the 2 bosses [3] of the arm cover 3 [2] with the Control panel arm
unit [1], and fix it in place with a screw (binding; M4X10) [4].
2-26
F-2-96
[1]
[4]
[3]
F-2-97
[2]
F-2-98
[3]
[2]
3) Route the control panel interface cable through the Control panel arm unit
[1], and fix it in place with the edge saddle [3].
[2]
4) Hook the claw [2] of the Control panel arm unit [1], and tighten the 4
screws (binding; M4X10) [3] and 4 screws [4].
0012-2067
- Be sure to tighten the screws in the correct order.
- Do not drop the screws.
5) Adjust the control panel interface cable [1] so that the length [4] from the
edge saddle [2] and the marking [3] is about 5 cm, and fix it in place using
the edge saddle.
[4]
[3]
[1]
F-2-99
[1]
[3]
F-2-100
[2]
[4]
[1]
[3]
[3]
F-2-101