Chapter 8
[3]
4) Remove the two screws [4], and detach the fixing feeding unit releasing
lever support plate [5].
[4]
5) Remove the E-ring [6], bearing [7], and three screws [8].
6) Remove the E-ring [9], gear [10], pin [11], three screws [12], E-ring [13],
and bearing [14].
[12]
8-46
[1]
[2]
[1]
F-8-120
[5]
[4]
F-8-121
[8]
[7]
[6]
F-8-122
[13]
[14]
[11]
[9]
[10]
F-8-123
7) Remove the feeding belt unit [15], and detach the feeding belt [16] and the
postcard belt [17].
[17]
[16]
[15]

8.11.22 Duplexing Unit

8.11.22.1 Removing the Duplexing Unit

iR7105 / iR7095 / iR7086
1) Slide out the duplexing unit from the main body.
2) Holding the left and right grips of the duplexing unit, detach it from the
main body.
Duplexing unit
Grip
Take care not to trap your hand between the grip and the rail. Do not place
the duplexing unit where it is subjected to damage.

8.11.22.2 Removing the Reversal Motor

iR7105 / iR7095 / iR7086
1) Remove the duplex feed fan unit.
2) Loosen the screw [1]; then, while pulling the tension support plate [2]
in the direction of the arrow, tighten the screw [1] (to loosen the tension
of the belt [2]).
3) Disconnect the connector [4], and remove the 2 screws [5]; then, de-
tach the reversal motor [6].
[1]
[2]
[5]
[16]
F-8-124
Grip
F-8-125
[3]
[6]
[5]
[4]
F-8-126
0010-9323