7) Move the mirror 1 mount [1] in the left direction until it stops at the original position.
8) Insert the cable clamp [1] into the hole [2] of the frame.
9) Attach the lens heater [1].
- 1 connector [2]
- 1 cable clamp [3]
- 1 screw (RS tightening; M4X8) [4]
F-2-199
F-2-200
F-2-201
F-2-202
Tighten the screw [3] while pushing the lens heater [1] in the direction of
the embossed section [2]. Be careful so that the claw [4] of the heater is not
removed. Make sure that the bottom of the heater firmly contacts with the
frame.