-Make sure not to use 1 through 1023 other than 80 (HTTP) as a port for MEAP. Because the ports in this range are used by general servers, there is a possibility
that the ports in this range will be duplicated in the future.
<Setting Procedure of Port on HTTP server>
1) Startup [SERVICE MODE] (After pressing [USER MODE] button of MEAP device, press [2] button and [8] button at the same time on control panel. Then
by pressing [USER MODE] button again, [SERVICE MODE] screen is displayed).
2) Startup level 2 of [SERVICE MODE] (After starting up [SERVICE MODE] in step 1, press [USER MODE] button again. Then, by pressing [2] button on
control panel, the screen is displayed.
3) Press [COPIER] button.
4) Press [Option] button.
5) Press [BODY] button.
6) Press [<-] button.
7) Press [MEAP-PN] button.
8) Press the port number to specify on the control panel (the numerical value input in the field is displayed), and press [OK] button.
9) Check to see that it is reflected in setting field, and turn off the main power, and then, turn on the main power.
<Setting Procedure of port on HTTPS server>