0000 After the power is turned on, the reading of the main thermistor fails to reach 70 deg C or more within 3.5 min.
E001 (overheating)
0001 The reading of the main or sub thermistor is 230 deg C or more for 2 sec (detection by hardware).
0002 The reading of the main or sub thermistor is 230 deg C or more for 2 sec (detection by software).
0003 The difference between the readings of the main thermistor and the sub thermistor is 50 deg C for 1 sec or more (main > sub).
0004 The difference between the readings of the main and the sub thermistor is 50 deg C for 1 sec or more (main >/= sub ).
E002 (heating failure)
0001 The reading of the main thermistor is 70 deg C or more but does not reach 100 deg C within 2.5 min.
0002 The reading of the main thermistor exceeds 100 deg C but does not reach 150 deg C within 2.5 min thereafter.
E003 (low temperature)
0000 With the reading of the main thermistor in excess of 100 deg C, a temperature of 70 deg C or less is detected for 2 sec.
E004 (SSR short circuit)
0000 The SSR is identified as having a short circuit for 5 sec or more while the sub heater is on.
0001 The SSR is identified as having a short circuit for 5 sec while the main heater is on.
Reference:
If E000 through E004 is indicated, the code will not be reset even when the main power switch is turned off. To reset, use service mode (COPIER > FUNCTION