Chapter 2
[1]
5) Mount the developing assembly locking plate [1].
- 2 bosses [2]
- 6 screws (TP; M4X6; black) [3]
[3]
[1]
[2]
Check to be sure that the developing assembly locking plate is free of a gap
and displacement, which are likely to cause image faults. (Especially, it
must not be riding over the bosses found below.)
When mounting the developing assembly locking plate, take care not to trap
the cable [1].
6) Slide out the 2 rails [1] of the pull-off unit.
[1]
2-20
[2]
F-2-61
[3]
[2]
F-2-62
[1]
[1]
F-2-63
7) Remove the tape from the pull-off unit.
8) Hold the pull-off unit [1] as follows, and hook the 4 holes [3] of the pull-
off unit on the 4 protrusions [2] of the rail.
[3]
[2]
[1]
9) Fix the extraction unit with the 2 screws (binding; M3X4) and push the
extraction unit until it locks.
[1]
10) Fit the reuse band [1] in the hole [2] of the host machine.
[1]
11) Connect the connector [1].
12) Attach the connector cover [1].
[2]
[3]
F-2-64
F-2-65
[2]
F-2-66
[1]
F-2-67