Canon iR7086 Series Service Manual page 158

Hide thumbs Also See for iR7086 Series:
Table of Contents

Advertisement

Chapter 3
Scanner home position
sensor PS1
Scanning lamp FL1
Scanner motor M4
Fixing main heater H1
Fixing sub heater H2
Fixing drive motor M3
Main motor M1
Drum motor M0
Pre-exposure LED
Primary charging
Grid bias
Developing bias DC
Developing bias AC
Bias roller
Pre-transfer charging
DC
Pre-transfer charging
AC
Transfer charging
Separation charging
Surface potential
measurement
Primary, pre-transfer, transfer,
separation, charging wire
cleaning motor
Period
WMUP (warm-up)
WMUPR (warm-up rotation)
3-4
Main power switch ON
Control panel power switch ON
183
(outside Jpn: 193 deg C)
WMUP
F-3-4
T-3-2
Description
From when the power switch is turned on to when the surface temperature of the fixing assembly reaches 193 degrees.
To execute potential stabilization control and surface potential control.
188
WMUPR
VD
VL
(outside Jpn: 198 deg C)
STBY