SERVICE MODE:
- COPIER> OPTION> BODY> FUZZY (enabling/disabling fuzzy control)
0: enables fuzzy control (default)
1: low humidity mode (the separation current is lower that standard)
2: normal humidity mode
3: high humidity environment mode (the separation current is higher than standard)
If set to '1' thorough '3', the control will be independent of the environment sensor.
7.9.1.3 Correcting the Output upon Detection of Leakage
iR7105 / iR7095 / iR7086
If leakage is detected, the separation output will be supplied at a lowered output level.
10.0 kvpp
COPIER > OPTION > BODY > SP-MODE
SERVICE MODE:
- COPIER> OPTION> BODY> SP-MODE (enabling/disabling separation current output correction control)
0: standard mode (AC output is 10.0 kVpp, default)
1: low voltage mode (AC output is 9.0 kVpp; if error is frequent because of leakage)
7.9.1.4 Others
iR7105 / iR7095 / iR7086
SERVICE MODE:
- CODIER> ADJUST> HV-SP> SP-N1 (output adjustment for plain paper simplexing or 1st side of duplexing)
If the DC controller PCB has been replaced or the RAM on the DC controller has been initialized, enter the value indicated on the service label.
- CODIER> ADJUST> HV-SP> SP-N2 (output adjustment for 2nd side of plain paper duplexing)
If the DC controller PCB has been replaced or the RAM on the DC controller has been initialized, enter the value indicated on the service label.
E068 indication
8.5 kvpp
NG
If leakage current is detected,
a retry is made with a lowered
output level.
Low voltage mode
Main power switchOFF/ON
9.0 kvpp
Setting
Leakage current is detected,
and a retry is made with a
lowered output level.
F-7-45
8.5 kvpp
Chapter 7
0010-8078
0010-8079
7-31