Click System Log System Logs.
1.
2.
Specify System Log Status, set the level of event messages to be logged to RAM and flash memory, then click Apply.
The page includes the following fields:
Object
• System Log Status
• Flash Level(0-7)
• RAM Level(0-7)
1.
2.
Figure 4-2-17 System Logs screenshot
Description
Enables/disables the logging of debug or error messages to the logging process.
(Default: Enabled)
Limits log messages saved to the switch's permanent flash memory for all levels
up to the specified level. For example, if level 3 is specified, all messages from
level 0 to level 3 will be logged to flash.
Range: 0-7,
Default: 3
Limits log messages saved to the switch's temporary RAM memory for all levels
up to the specified level. For example, if level 7 is specified, all messages from
level 0 to level 7 will be logged to RAM.
Range: 0-7,
Default: 7
There are only Level 2, 5 and 6 error messages for the current firmware release.
The Flash Level must be equal to or less than the RAM Level.
70
User's Manual of IGSW-2840