Planet IGSW-2840 User Manual page 379

24-port 10/100mbps + 4 gigabit tp/sfp combo industrial managed switch
Table of Contents

Advertisement

timeout login response [seconds] no timeout login response
seconds - Integer that specifies the timeout interval.
(Range: 0 -300 seconds; 0: disabled)
Default Setting
CLI: Disabled (0 seconds)
Telnet: 600 seconds
Command Mode
Line Configuration
Command Usage
If a login attempt is not detected within the timeout interval, the connection is terminated for the session.
This command applies to both the local console and Telnet connections.
The timeout for Telnet cannot be disabled.
Using the command without specifying a timeout restores the default setting.
Example
To set the timeout to two minutes, enter this command:
Console(config-line)#timeout login response 120
Console(config-line)#
Related Commands
silent-time
exec-timeout
exec-timeout
This command sets the interval that the system waits until user input is detected. Use the no form to restore the default.
Syntax
exec-timeout [seconds] no exec-timeout
seconds - Integer that specifies the number of seconds.
(Range: 0-65535 seconds; 0: no timeout)
Default Setting
CLI: No timeout
Telnet: 10 minutes
Command Mode
Line Configuration
Command Usage
If user input is detected within the timeout interval, the session is kept open; otherwise the session is terminated.
This command applies to both the local console and Telnet connections.
The timeout for Telnet cannot be disabled.
379
User's Manual of IGSW-2840

Advertisement

Table of Contents
loading

Table of Contents