The page includes the following fields:
Object
• Path Cost Method
• Transmission Limit
■ Configuration Settings for MSTP
The page includes the following fields:
Object
• Max Instance Numbers
• Configuration Digest
• Region Revision
• Region Name
Description
The path cost is used to determine the best path between devices. The path cost
method is used to determine the range of values that can be assigned to each
interface.
-
Long: Specifies 32-bit based values that range from 1-200,000,000.
(This is the default.)
-
Short: Specifies 16-bit based values that range from 1-65535.
The maximum transmission rate for BPDUs is specified by setting the minimum
interval between the transmission of consecutive protocol messages.
Range: 1-10;
Default: 3
Figure 4-7-5 MSTP Configuration screenshot
Description
The maximum number of MSTP instances to which this Industrial Managed
Switch can be assigned.
An MD5 signature key that contains the VLAN ID to MST ID mapping table. In
other words, this key is a mapping of all VLANs to the CIST.
The revision for this MSTI.
Range: 0-65535;
Default: 0
The name for this MSTI.