    Table of Contents 1. Package Contents ..............3 2. Requirements ................4 3. Wiring the Power Inputs ............5 4. Terminal Setup (IGS-4215-16T2S only) ........7 4.1 Logging on to the Console ........... 8 4.2 Configuring IP Address via the Console ......... 9 4.3 Storing Current Switch Configuration ........11 4.4 SSH Login (IGS-4215-8T2S and IGS-4215-4T2S) ....12 5.
  • Page 3: Package Contents

    1. Package Contents Thank you for purchasing PLANET Industrial L2/L4 Managed Gigabit Ethernet Switch, IGS-4215 series. The descriptions of these models are as follows: 10/100/1000T 100/1000X Models RJ45 Ports SFP Ports IGS-4215-4T2S IGS-4215-8T2S IGS-4215-16T2S “Industrial Managed Switch” mentioned in this Quick Installation Guide refers to the IGS-4215 series. Open the box of the Industrial Managed Switch and carefully unpack it. The box should contain the following items: Industrial Managed Quick Installation Wall-mount Plate Switch x 1...
  • Page 4: Requirements

    2. Requirements The Industrial Managed Switch provides local and remote login interface for management purposes. The following equipment is necessary for further management: z Workstations running Windows XP/2003/Vista/7/8/10/2008/10, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols. z Workstations are installed with Ethernet NIC (Network Interface Card) z Serial Port Connection (Terminal)  The above Workstations come with COM Port (DB9) or USB-to-...
  • Page 5: Wiring The Power Inputs

    3. Wiring the Power Inputs The Upper Panel of the Industrial Managed Switch consists of one terminal block connector within 6 contacts for two redundant power inputs and fault alarm. Please follow the steps below to insert the power wire. 1. Insert positive/negative DC power wires into contacts 1 and 2 for Power 1 or 5 and 6 for Power 2.
  • Page 6  IGS-4215-4T2S Max. Fault Alarm Loading: 24V, 1A 1 2 3 4 5 6 DC Input: 9-48V , 1A max. AC Input: 24V , 0.6A max. PWR1 Alarm PWR2 Figure 3-3: IGS-4215-4T2S Inlet Power Socket 2. Tighten the wire-clamp screws for preventing the wires from loos- ening.
  • Page 7: Terminal Setup (Igs-4215-16T2S Only)

    4. Terminal Setup (IGS-4215-16T2S only) To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to the RJ45 type serial (console) port of the Industrial Managed Switch. PC / Workstation with Terminal Emulation Software Managed Switch RS232 to RJ45 Cable Serial Port RJ45 Console Port Figure 4-1: Industrial Managed Switch Console Connectivity A terminal program is required to make the software connection to the Industrial Managed Switch.
  • Page 8: Logging On To The Console

    4.1 Logging on to the Console Once the terminal has been connected to the device, power on the Industrial Managed Switch and the terminal will display “running testing procedures”. Then, the following message asks to log in user name and password. The factory default user name and password are shown in Figure 4-1 below. Username: admin Password: admin Figure 4-1: Industrial Managed Switch Console Login Screen The user can now enter commands to manage the Industrial Managed Switch. For a detailed description of the commands, please refer to the following chapters.
  • Page 9: Configuring Ip Address Via The Console

    4.2 Configuring IP Address via the Console The Industrial Managed Switch is shipped with default IP address as follows: IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Industrial Managed Switch, please use the procedures as follows:  Display of current IP address 1. At the “IGS-4215-16T2S#” prompt, enter “show ip”. 2. The screen displays the current IP address, subnet mask and gateway as shown in Figure 4-2.
  • Page 10  Configuration of the IP address 1. At the “IGS-4215-16T2S #” prompt, enter “configure”. 2. At the “IGS-4215-16T2S (config)#” prompt, enter the following command and press <Enter> as shown in Figure 4-3. IGS-4215-16T2S (config)# ip address 192.168.1.100 mask 255.255.255.0 IGS-4215-16T2S (config)# ip default-gateway 192.168.1.254 The previous command would apply the following settings for the Industrial Managed Switch. IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Gateway: 192.168.1.254 Figure 4-3: Configuring IP Address Screen 3. Repeat Step 1 to check if the IP address has changed.
  • Page 11: Storing Current Switch Configuration

    4.3 Storing Current Switch Configuration At the “IGS-4215-16T2S #” prompt, enter “copy running-config startup-config” as shown in Figure 4-4. Figure 4-4: Saving Current Configuration Command Screen If you are not familiar with console command or the related parameter, enter “?” anytime in console to get the help description. Note...
  • Page 12: Ssh Login (Igs-4215-8T2S And Igs-4215-4T2S)

    4.4 SSH Login (IGS-4215-8T2S and IGS-4215-4T2S) The IGS-4215-8T2S and IGS-4215-4T2S also support SSHv2 for secure remote management as default. The switch asks for user name and password for remote login when using telnet; please use “admin” for both username and password. Default IP address: 192.168.0.100 Username: admin Password: admin Figure 4-5: Industrial Managed Switch SSH Login Screen The user can now enter commands to manage the Industrial Managed Switch. For a detailed description of the commands, please refer to Chapters 4-2 and 4-3.
  • Page 13: Starting Web Management

    5. Starting Web Management The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address. For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the...
  • Page 14: Logging In To The Industrial Managed Switch

    5.1 Logging in to the Industrial Managed Switch 1. Use Internet Explorer 8.0 or above Web browser and enter IP address https://192.168.0.100 to access the Web interface. 2. When the following dialog box appears, please enter the default user name and password “admin”. The login screen in Figure 5-2 appears.
  • Page 15 The Switch Menu on the left of the Web page lets you access all the commands and statistics the Industrial Managed Switch provides. Figure 5-4: Switch Menu Now, you can use the Web management interface to continue the Switch management. Please refer to the user’s manual for more.
  • Page 16: Saving Configuration Via The Web

    5.2 Saving Configuration via the Web To save all applied changes and set the current configuration as a startup configuration, the startup-configuration file will be loaded automatically across a system reboot. 1. Click “Save > Save Configurations to FLASH” to log in to the “Configuration Manager” page.
  • Page 17: Recovering Back To Default Configuration

    6. Recovering Back to Default Configuration  IP Address has been changed or admin password has been forgotten – To reset the IP address to the default IP Address “192.168.0.100” or reset the login password to default value, press the hardware reset button on the front panel for about 10 seconds. After the device is rebooted, you can log in the management Web interface within the same subnet of 192.168.0.xx.
  • Page 18  IGS-4215-4T2S P2 Alarm Ring R.O. Reset Button Reset 1000 10/100 1000 LNK/ACT LNK/ACT Figure 6-1: Reset Button...
  • Page 19: Customer Support

    7. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource and User’s Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.