SP5-XXX (Mode)

5024
[mm / inch Display]
5024 001
5040
[Free Size main] Free Size Main Scan DFU
5040 001
By-pass
5040 002
Tray1
5040 003
Tray2
5040 004
Tray3
5041
[Free Size Sub] Free Size Sub Scan DFU
5041 001
By-pass
5041 002
Tray1
5041 003
Tray2
5041 004
Tray3
5045
[Accounting count]
5045 001
Counter Method
5051
[Toner Refill Displ] Toner Refill Display
5051 001
5055
[Display IP Address] IP Address Display
5055 001
5150
[Bypass Length Se] By-pass Length Setting
5801 001
SM
CÓPIA NÃO CONTROLADA
*CTL
Sets units (mm or inch) for custom paper
sizes.
[0 or 1 / 1 /-]
0: mm (EU/AS), 1: inch (NA)
*CTL
Displays the width of the custom paper size
that is set by the user.
*CTL
[0.0 to 297.0 / 215.9 / 0.1 mm/step]
*CTL
*CTL
*CTL
Displays the length of the custom paper size
that is set by the user.
*CTL
[0.0 to 297.0 / 279.4 / 0.1 mm/step]
*CTL
*CTL
*CTL
Selects the counting method if the meter
charge mode is enabled with SP5-930-001.
You can change the setting only one time.
[0 to 1 / 1 / -]
0: Developments, 1: Pages
*CTL
Enable or disable the toner refill display.
[0 to 1 / 0 / -]
0: enable, 1: disable
*CTL
Displays the IP address on the second line of
the operation panel when the printer is in the
Ready condition.
[0 to 1 / 0 / -]
0: Off, 1: On
NOTE: This SP Mode requires:
Websys v1.05 or later (P/N G1045235C)
Controller v1.07.2 or later (P/N G1045239F)
Printer v1.07.2 or later (P/N G1045243F)
-
Lets or does not let the by-pass tray feed
extra long paper (up to 1260 mm).
[0 to 1 / 0 / -] Alphanumeric
0: Off, 1: On