Ricoh G104 Service Manual page 420

G104; g160; g161
Table of Contents

Advertisement

Service Mode Table
2202 003
RS: [C]
2202 004
RS: [Y]
2202 006
LS: [K]
2202 007
LS: [M]
2202 008
LS: [C]
2202 009
LS: [Y]
2202 011
Output Control
2202 012
Interval
[Charge Bias: AC] Charge Roller Voltage: AC/I
(Process Speed, [Color]) Process Speed -> LS: Low speed, RS: Regular
2203
speed
These SPs adjust the AC/I bias of the drum charge roller. These are used only
when SP3-501-001 is set to "1".
2203 001
RS: [K]
2203 002
RS: [M]
2203 003
RS: [C]
2203 004
RS: [Y]
[Charge Bias] Charge Roller Voltage: Corrections for humidity
(Environmental correction, [Color])
2204
For more about the humidity conditions, see SP 2304.
Adds these environment correction coefficients to the charge bias.
2204 001
Environ. : HH: [K]
2204 002
Environ. : HH: [M]
2204 003
Environ. : HH: [C]
G160/G161
CÓPIA NÃO CONTROLADA
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
Selects the method for the charge roller
AC bias adjustment.
*EGB
[0 or 1 / 0 / -]
0: Process Control, 1: Setting
Adjusts the interval for charge roller AC
*EGB
bias adjustment.
[0 to 2000 / 210 / 1 sheet/step]
[0 to 1.5 / P2a: 0.49, P2b: 0.30 / 0.01
*EGB
mA/step]
[0 to 1.5 / P2a: 0.48, P2b: 0.30 / 0.01
*EGB
mA/step]
[0 to 1.5 / P2a: 0.49, P2b: 0.30 / 0.01
*EGB
mA/step]
[0 to 1.5 / P2a: 0.48, P2b: 0.30 / 0.01
*EGB
mA/step]
*EGB
[0 to 255 / P2a: 109, P2b: 204 / 1%/step]
*EGB
[0 to 255 / P2a: 107, P2b:196 / 1%/step]
*EGB
[0 to 255 / P2a: 104, P2b: 197 / 1%/step]
5-40
CÓPIA NÃO CONTROLADA
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G160G161

Table of Contents