Ricoh G104 Service Manual page 419

G104; g160; g161
Table of Contents

Advertisement

2186 005
Minute
2186 006
Temperature
2186 007
Result
2186 008
Execution
2186 009
Failure
[MUSIC Result] Automatic Line Position Adjustment Result
2187
The following SPs display the skew adjustment values after the line position
adjustment have been done.
2187 001
[K]:Skew Adj.
2187 002
[M]:Skew Adj.
2187 003
[C]:Skew Adj.
2187 004
[Y]:Skew Adj.
[Charge Bias: DC] Charge Roller Voltage: DC
(Process Speed, [Color]) Process Speed LS: Low speed, RS: Regular speed
2201
These SPs adjust the DC voltage of the drum charge roller. These are used
only when SP3-501-001 is set to "1".
2201 001
RS: [K]
2201 002
RS: [M]
2201 003
RS: [C]
2201 004
RS: [Y]
2201 006
LS: [K]
2201 007
LS: [M]
2201 008
LS: [C]
2201 009
LS: [Y]
[Charge Bias: AC] Charge Roller Voltage: AC
(Process Speed, [Color]) Process Speed -> LS: Low speed, RS: Regular
speed
2202
These SPs adjust the AC voltage of the drum charge roller. These are used
only when SP2-202-011 is set to "1".
2202 001
RS: [K]
2202 002
RS: [M]
SM
CÓPIA NÃO CONTROLADA
*EGB
[0 to 59 / 0 / 1 y/step]
*EGB
[0 to 100 / 0 / 1°C/step]
*EGB
[0 to 999999 / 0 / 1 /step]
*EGB
[0 to 9999 / 0 / 1 /step]
*EGB
[0 to 9999 / 0 / 1 /step]
*EGB
*EGB
[-99 to 99 / 0 / 1 click/step]
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
[200 to 999 / 585 / 1 V/step]
*EGB
*EGB
*EGB
*EGB
*EGB
[0 to 3000 / 2000 / 1 V/step]
*EGB
5-39
CÓPIA NÃO CONTROLADA
Service Mode Table
G160/G161

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G160G161

Table of Contents