Ricoh G104 Service Manual page 175

G104; g160; g161
Table of Contents

Advertisement

5505
[Error Alarm]
5505 001
5507
[Supply Alarm]
5507 001
Paper Supply Ala
5507 003
Toner Supply Ala
5507 128
Interval: Others
5507 133
Interval: A4
5507 134
Interval: A5
5507 142
Interval: B5
5507 164
Interval: LG
5507 166
Interval: LT
5507 172
Interval: HLT
5801
[Memory Clear]
5801 001
All
5801 002
Engine
5801 003
SCS
5801 004
IMH
5801 005
MCS
5801 008
PRT
5801 010
Web Service
5801 011
NCS
5801 014
DCS Setting
SM
CÓPIA NÃO CONTROLADA
*CTL
Sets the error alarm level. If an SC code
occurs, the error alarm counter increases by
+1. If no SC code occurs while the set
number of paper is output, the jam alarm
counter decreases by -1. The error alarm
occurs when the error alarm counter reaches
+5.
[0 to 255 / 30 / 1/step]
0: Disables the PM alarm
The alert is sent to the e-mail address that is
specified for the system administrator using
a browser and the built-in web server (Web
Image Monitor).
When SP5-866-001 is set to 1, this SP is
enabled.
*CTL
Enables or disables the supply alarm.
[0 to 1 / 0 / -] Alphanumeric
-
0: Off, 1: On
*CTL
Sets the paper supply alarm level. A paper
supply alarm counter increases by +1 when
*CTL
a sheet of the related size is used. The paper
*CTL
supply alarm occurs when one of the paper
*CTL
supply alarm counters gets to the set value.
*CTL
[250 to 10000 / 1000 / 1/step]
*CTL
The alert is sent to the e-mail address that is
*CTL
specified for the system administrator using
a browser and the built-in web server (Web
Image Monitor).
When SP5-866-001 is set to 1, this SP is
enabled.
-
Resets the SP5801-002 through 016 except
the security related data in 003, 010, 011and
015. These cannot be reset with SP mode.
-
Resets or deletes the engine-related data.
-
Clears the system settings.
-
Clears IMH data. DFU
-
Clears MCS data. DFU
-
Clears the printer application settings.
*CTL
Clears the web service data and the network
application data.
*CTL
Initializes the system default and interface
settings (IP address also), SmartNetMonitor
for Admin, WebStatusMonitor settings, and
the TELNET settings.
*CTL
Resets or deletes the DCS-related data.
5-59
CÓPIA NÃO CONTROLADA
ENGINE SERVICE MODE
G104

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G160G161

Table of Contents