Ricoh G104 Service Manual page 150

G104; g160; g161
Table of Contents

Advertisement

SERVICE MODE TABLE
[Normal2: [K]] Transfer roller current and discharge plate voltage for the image
area, plain paper 2, black toner
2433
(Process Speed, Paper Side) Process Speed -> LS: Low speed,
Paper Side: 1st or 2nd
2433 007
LS: 1st: T. Roll 2
2433 008
LS: 1st: Separa.
2433 012
LS: 2nd: T. Roll 2
2433 013
LS: 2nd: Separa.
[Normal2: [FC]] Transfer roller current and discharge plate voltage for the
image area, plain paper 2, CMY toner
2437
(Process Speed, Paper Side) RS: Regular Speed, Paper Side: 1st or 2nd
2437 013
RS: 1st: T. Roll 2
2437 014
RS: 1st: Separa.
2437 021
RS: 2nd: T. Roll 2
2437 022
RS: 2nd: Separa.
[Normal2: [FC]] Transfer roller current and discharge plate voltage for the
image area, plain paper 2, CMY toner
2438
(Process Speed, Paper Side) LS: Low Speed, Paper Side: 1st or 2nd
2438 013
LS: 1st: T. Roll 2
2438 014
LS: 1st: Separa.
2438 021
LS: 2nd: T. Roll 2
2438 022
LS: 2nd: Separa.
[Normal2:[K]:LE] Transfer roller current and discharge plate voltage for the
leading edge area, plain paper 2, black toner
2451
Paper Side: 1st or 2nd
Unit -> T.Roll2: Transfer roller, Separation: Discharge plate (paper separation)
2451 003
Separation
2451 007
Trans.Roll2: 1st
2451 012
Trans.Roll2: 2nd
[Switch Timing] Switch timing from leading edge to normal, plain paper 2
2452
(Paper Type, Edge) Paper Type -> N: Normal, LE: Leading Edge
2452 002
T. Roll 2: N2: LE
2452 003
Separation: N2: LE
G104
CÓPIA NÃO CONTROLADA
*EGB
Adjusts the transfer roller current.
[0 to 60 / 10.0 / 0.1 -µA/step]
*EGB
Adjusts the discharge plate voltage.
[0 to 4 / 2.0 / 0.1 -KV/step]
*EGB
[0 to 60 / 7.5 / 0.1 -µA/step]
*EGB
[0 to 4 / 2.0 / 0.1 -KV/step]
*EGB
Adjusts the transfer roller current.
[0 to 60 / 20.0 / 0.1 -µA/step]
*EGB
Adjusts the discharge plate voltage.
[0 to 4 / 2.0 / 0.1 -KV/step]
*EGB
[0 to 60 / 20.0 / 0.1 -µA/step]
*EGB
[0 to 4 / 2.0 / 0.1 -KV/step]
*EGB
Adjusts the transfer roller current.
[0 to 60 / 10.0 / 0.1 -µA/step]
*EGB
Adjusts the discharge plate voltage.
[0 to 4 / 2.0 / 0.1 -KV/step]
*EGB
[0 to 60 / 15.0 / 0.1 -µA/step]
*EGB
[0 to 4 / 2.0 / 0.1 -KV/step]
*EGB
[0 to 400 / 100 / 5%/step]
*EGB
*EGB
*EGB
[0 to 200 / 10 / 1 mm/step]
*EGB
[0 to 200 / 25 / 1 mm/step]
5-34