Service Mode Table
2181 006
[K]: M Cor.: SubD.
2181 007
[K]: S Cor.: 600
2181 008
[K]: S Cor.: 1200
2181 011
[M]: Skew
2181 012
[M]: Bent
2181 013
[M]: M. Scan Erro.
2181 014
[M]: S. Scan Erro.
2181 015
[M]: M Cor.: Dot
2181 016
[M]: M Cor.: SubD.
2181 017
[M]: S Cor.: 600
2181 018
[M]: S Cor.: 1200
2181 021
[C]: Skew
2181 022
[C]: Bent
2181 023
[C]: M. Scan Erro.
2181 024
[C]: S. Scan Erro.
2181 025
[C]: M Cor.: Dot
2181 026
[C]: M Cor.: SubD.
2181 027
[C]: S Cor.: 600
2181 028
[C]: S Cor.: 1200
2181 031
[Y]: Skew
2181 032
[Y]: Bent
2181 033
[Y]: M. Scan Erro.
2181 034
[Y]: S. Scan Erro.
2181 035
[Y]: M Cor.: Dot
2181 036
[Y]: M Cor.: SubD.
2181 037
[Y]: S Cor.: 600
2181 038
[Y]: S Cor.: 1200
[MUSIC Record] Automatic Line Position Adjustment Record
2186
The following SPs display the MUSIC record.
2186 001
Year
2186 002
Month
2186 003
Date
2186 004
Time
G160/G161
CÓPIA NÃO CONTROLADA
*EGB
*EGB
[-127 to 127 / 0 / 1 line/step]
*EGB
*EGB
*EGB
[-5000 to 5000 / 0 / 1 micrometer /step]
*EGB
*EGB
*EGB
[-127 to 127 / 0 / 1 dot/step]
*EGB
[-15 to 15 / 0 / 1 sub-dot/step]
*EGB
[-127 to 127 / 0 / 1 line/step]
*EGB
*EGB
*EGB
[-5000 to 5000 / 0 / 1 micrometer/step]
*EGB
*EGB
*EGB
[-127 to 127 / 0 / 1 dot/step]
*EGB
[-15 to 15 / 0 / 1 sub-dot/step]
*EGB
[-127 to 127 / 0 / 1 line/step]
*EGB
*EGB
*EGB
[-999 to 999 / 0 / 1 micrometer/step]
*EGB
*EGB
*EGB
[-127 to 127 / 0 / 1 dot/step]
*EGB
[-15 to 15 / 0 / 1 sub-dot/step]
*EGB
[-127 to 127 / 0 / 1 line/step]
*EGB
*EGB
[0 to 99 / 0 / 1 y/step]
*EGB
[1 to 12 / 1 / 1 m/step]
*EGB
[1 to 31 / 1 / 1 d/step]
*EGB
[0 to 23 / 0 / 1 h/step]
5-38