Paper Feed. Temp.
1104 023
Adjusts the increase in the temperature of the fusing unit between the ready
condition and the start of paper feed at the start of a new job.
1st Add Time: LS
For print jobs at low speed. If the interval between jobs is less than this setting,
1104 024
then the temperature change (1104 025) for the first page of a new job is not
applied.
1st Add Temp.
Adds this value to the basic fusing temperature, for the first page of a new job.
1104 025
This extra temperature is necessary because when the printer starts the first
page, the fusing unit is not warm enough.
1st Temp. Maint.
1104 026
Adjusts the time for maintaining the temperature change that is set with 1104
025.
1st Print Inter.
For print jobs at regular speed. If the interval between jobs is less than this
1104 027
setting, then the temperature change (1104 025) for the first page of a new job
is not applied.
Paper Feed. Temp.
1104 028
Adjusts the increase in the temperature of the fusing unit between the ready
condition and the start of paper feed at the start of a new job (B/W mode).
1st PrtDecTmpTime
1104 029
Adjusts the time for decreasing 1°C when the temperature decline to the target
printing temperature.
PreRot.Thre.Temp.
1104 030
Adjusts the threshold temperature for the added idling rotation.
1st PrtDecTmpTime
1104 031
Adjusts the added idling rotation time. This SP is activated when the fusing
temperature does not reach the specified temperature with SP1104-30.
[Fusing Temp.] Fusing Temperature
(Paper Type, Mode, Color, Process Speed)
1105
Paper Type -> N: Plain paper 1, N2: Plain paper 2, TC: Thick, TN: Thin, SP:
Special, OHP, ENV: Envelope, GL: Glossy paper, TK2: Thick paper 2
Mode -> Simple [one-sided] or Duplex
SM
CÓPIA NÃO CONTROLADA
*EGB
[0 to 30 / P2a: 5, P2b: 10 / 1/step]
[0 to 50 / 0 / 0.1 sec/step]
*EGB
[0 to 20 / P2a: 2, P2b: 8 / 1°C/step]
*EGB
[0 to 50 / P2a: 15, P2b: 8 / 1 sec/step]
*EGB
[0 to 100 / P2a: 0.2, P2b: 0 / 0.1 sec/step]
*EGB
[0 to 30 / 5 / 0.1 deg/step]
*EGB
[0 to 255 / P2a: 0, P2b: 3 / 1 sec/step]
*EGB
[0 to 255 / 20 / 1 deg/step]
*EGB
[0 to 255 / 2 / 1 sec/step]