ENGINE SERVICE MODE
9908
[Background Po.] Background potential
9908 001
Upper Limit
9908 002
Lower Limit
9910
[Charge Output]
9910 001
Charge Output
[Toner Fill Up]
9910 003
[All]
[TC Initial] Toner Cartridge Initial
9910 004
[All]
9910 005
[K]
9910 006
[M]
9910 007
[C]
9910 008
[Y]
[Toner Fill Up]
9910 010
[K]
9910 011
[M]
9910 012
[C]
9910 013
[Y]
9910 020
Upper Limit
9911
[TC Initial] Toner Cartridge Initial
9911 001
Maximum Repeat
9911 002
Threshold
9912
[ST Sensor]
9912 001
read
G104
CÓPIA NÃO CONTROLADA
*EGB
Adjusts the upper limit vale of background
potential.
[0 to 300 / 130 / 1/step]
*EGB
Adjusts the lower limit vale of background
potential.
[0 to 300 / 130 / 1/step]
-
Performs the charge output.
-
Fills up the toner for all colors.
-
Initializes the all toner bottles for each mode.
-
-
-
-
-
Fills up the toner for each color.
-
-
-
*EGB
Adjusts the upper limit for filling up the toner.
If the toner is detected for [N] times, the
toner fill up mode ends.
[N] can be adjusted with this SP9910-020.
[1 to 5 / 3 / 1/step]
*EGB
[1 to 30 / 15 / 1/step]]
*EGB
[1 to 100 / 20 / 0.01V/step]
-
Detects ST sensor output.
5-94
CÓPIA NÃO CONTROLADA