SERVICE MODE TABLE
1911 028
Duplex Temp.: S2
[Fusing Rotat.] Fusing Unit Roller Rotation Control
1912
Paper Type -> TC1: Thick paper 1, TC2: Thick paper 2, OHP, SP: Special
1912 001
Rotation
When the printer is in the ready condition, the nip between the hot roller and
pressure roller is in the same position. This may cause deformation of the
rollers. Therefore, a temporary rotation prevents this problem. SP 1912 001
turns this feature on or off. SP1912-003 and 004 control this rotation.
Pre-rotation: Fusing idling
1912 002
Prerotat. Speed
Adjusts the speed of the fusing-unit rollers during fusing idling.
0: 1/3 regular speed, 1: Low speed, 2: Regular speed
1912 003
Rotation Freque.
Adjusts the frequency of the fusing-unit roller rotation if the machine is in the
ready condition for a very long interval.
1912 004
Rotation Inter.
Adjusts the duration of the fusing-unit roller rotation
1912 005
Prerotat. Temp.
Fusing idling is not done if the fusing unit temperature is above this value.
1912 006
Prerotat. Inter.
Adjusts the duration of fusing idling immediately after the power is turned on.
1912 007
Ex. Rotation Time
Adjusts the time for extra rotation of the fusing unit rollers at the end of a job. If
the fusing motor stops before the fusing lamp turns off, the temperature can
become very high.
1912 008
Prerotat. Ext.
Adjusts the additional time for pre-rotation of the fusing rollers.
1912 010
TC1: Rotat. Ext.
Adjusts the additional time of the fusing roller pre-rotation for thick paper 1.
1912 011
TC2 Rotat. Ext.
Adjusts the additional time of the fusing roller pre-rotation for thick paper 2.
1912 012
OHP: Rotat. Ext.
Adjusts the additional time of the fusing roller pre-rotation for OHP.
1912 013
SP: Rotat. Ext.
Adjusts the additional time of the fusing roller pre-rotation for special paper.
1913
[Heating Roller] Heating Roller Control
1913 002
Stand-by Temp.
Adjusts the heating roller temperature when the machine is in the ready
condition.
G104
CÓPIA NÃO CONTROLADA
*EGB
[0 to 500 / 20 / 1 sheet/step]
*EGB
[0 or 1 / 1 / -]
0: Off 1: On.
*EGB
[0 to 2 / 2 / -]
*EGB
[1 to 24 / 4 / 1 hour/step]
*EGB
[0 to 25 / 0.1/ 0.1 sec/step]
*EGB
[0 to 200 / 100 / 1°C/step]
*EGB
[0 to 180 / 1 / 1 min/step]
*EGB
[0 to 10 / 5 / 1 sec/step]
*EGB
[0 to 255 / 0 / 1 sec/step]
*EGB
[0 to 255 / 10 / 1 sec/step]
*EGB
[0 to 255 / 15 / 1 sec/step]
*EGB
[0 to 255 / 15 / 1 sec/step]
*EGB
[0 to 255 / 15 / 1 sec/step]
*EGB
[0 to 200 / 150 / 1°C/step]
5-18