[Normal: [K]] Transfer roller current and discharge plate voltage for the image
area of plain paper 1 in B/W mode
2403
(Process Speed, Paper Side) Process Speed -> LS: Low speed,
Paper Side: 1st or 2nd
2403 007
LS: 1st: T. Roll2
2403 008
LS: 1st: Separa.
2403 012
LS: 2nd: T. Roll2
2403 013
LS: 2nd: Separa.
[Normal: [FC]] Transfer roller current and discharge plate voltage for the
image area of plain paper 1 in color mode
2407
(Process Speed, Paper Side) Process Speed -> RS: Regular speed,
Paper Side: 1st or 2nd
2407 013
RS: 1st: T. Roll2
2407 014
RS: 1st: Separa.
2407 021
RS: 2nd: T. Roll2
2407 022
RS: 2nd: Separa.
[Normal: [FC]] Transfer roller current and discharge plate voltage for the
image area of plain paper 1 in color mode
2408
(Process Speed, Paper Side) Process Speed -> LS: Low speed,
Paper Side: 1st or 2nd
2408 013
LS: 1st: T. Roll2
2408 014
LS: 1st: Separa.
SM
CÓPIA NÃO CONTROLADA
Adjusts the transfer roller current.
*EGB
[0 to 60 / P2a 15.0/17.5 (NA/EU), P2b:
15.3/12.5 (NA/EU) / 0.1 -µA /step]
Adjusts the discharge plate voltage.
*EGB
[0 to 4 / 2.0 / 0.1 -KV/step]
[0 to 60 / P2a 15.0/12.5 (NA/EU), P2b:
*EGB
15.3/12.5 (NA/EU) / 0.1 -µA /step]
*EGB
[0 to 4 / 2.0 / 0.1 -KV/step]
Adjusts the transfer roller current.
*EGB
[0 to 60 / P2a 27.5/25.0 (NA/EU), P2b:
30.2/27.3 (NA/EU) / 0.1 -µA /step]
Adjusts the discharge plate voltage.
*EGB
[0 to 4 / 2.0 / 0.1 -KV/step]
[0 to 60 / P2a 25.0/27.5 (NA/EU), P2b:
*EGB
25.5/30.2 (NA/EU) / 0.1 -µA /step]
*EGB
[0 to 4 / 2.0 / 0.1 -KV/step]
Adjusts the transfer roller current.
*EGB
[0 to 60 / P2a 20.0/17.5 (NA/EU), P2b: 21.3
/ 0.1 -µA /step]
*EGB
Adjusts the discharge plate voltage.