2915 001
LL: RS [K]: 1st
2915 002
LL: RS [K]: 2nd
2915 003
LL: RS [FC]: 1st
2915 004
LL: RS [FC]: 2nd
2915 005
LL: LS [K]: 1st
2915 006
LL: LS [K]: 2nd
2915 007
LL: LS [FC]: 1st
2915 008
LL: LS [FC]: 2nd
2915 009
MM: RS [K]: 1st
2915 010
MM: RS [K]: 2nd
2915 011
MM: RS [FC]: 1st
2915 012
MM: RS [FC]: 2nd
2915 013
MM: LS [K]: 1st
2915 014
MM: LS [K]: 2nd
2915 015
MM: LS [FC]: 1st
2915 016
MM: LS [FC]: 2nd
2915 017
HH: RS [K]: 1st
2915 018
HH: RS [K]: 2nd
2915 019
HH: RS [FC]: 1st
2915 020
HH: RS [FC]: 2nd
2915 021
HH: LS [K]: 1st
2915 022
HH: LS [K]: 2nd
2915 023
HH: LS [FC]: 1st
2915 024
HH: LS [FC]: 2nd
[T2:GL2:Size5] Transfer Roller Current: Correction for Humidity, Glossary
paper2, Paper width A6 or less
(Environment, Process Speed, [Color]) LS: Low Speed, RS: Regular Speed
2916
The value displayed on the LCD is different from these SP's values.
For example, "20%" on the LCD actually means 100%.
2916 001
LL: RS [K]: 1st
2916 002
LL: RS [K]: 2nd
2916 003
LL: RS [FC]: 1st
SM
CÓPIA NÃO CONTROLADA
*EGB
[0 to 1275 / P2a: 135, P2b: 160 / 5%/step]
*EGB
[0 to 1275 / P2a: 195, P2b: 220 / 5%/step]
*EGB
[0 to 1275 / P2a: 165, P2b: 130 / 5%/step]
*EGB
[0 to 1275 / P2a: 190, P2b: 185 / 5%/step]
*EGB
[0 to 1275 / P2a: 130, P2b: 135 / 5%/step]
*EGB
[0 to 1275 / P2a: 200, P2b: 175 / 5%/step]
*EGB
[0 to 1275 / P2a: 120, P2b: 165 / 5%/step]
*EGB
[0 to 1275 / P2a: 215, P2b: 235 / 5%/step]
*EGB
[0 to 1275 / P2a: 140, P2b: 130 / 5%/step]
*EGB
[0 to 1275 / P2a: 250, P2b: 265 / 5%/step]
*EGB
[0 to 1275 / P2a: 155, P2b: 125 / 5%/step]
*EGB
[0 to 1275 / P2a: 245, P2b: 310 / 5%/step]
*EGB
[0 to 1275 / P2a: 120, P2b: 150 / 5%/step]
*EGB
[0 to 1275 / P2a: 255, P2b: 300 / 5%/step]
*EGB
[0 to 1275 / P2a: 130, P2b: 145 / 5%/step]
*EGB
[0 to 1275 / P2a: 290, P2b: 350 / 5%/step]
*EGB
[0 to 1275 / P2a: 125, P2b: 450 / 5%/step]
*EGB
[0 to 1275 / P2a: 270, P2b: 400 / 5%/step]
*EGB
[0 to 1275 / P2a: 110, P2b: 165 / 5%/step]
*EGB
[0 to 1275 / P2a: 260, P2b: 310 / 5%/step]
*EGB
[0 to 1275 / P2a: 125, P2b: 350 / 5%/step]
*EGB
[0 to 1275 / P2a: 295, P2b: 465 / 5%/step]
*EGB
[0 to 1275 / P2a: 125, P2b: 290 / 5%/step]
*EGB
[0 to 1275 / 335 / 5%/step]
*EGB
[0 to 1275 / P2a: 200, P2b: 160 / 5%/step]
*EGB
[0 to 1275 / P2a: 270, P2b: 235 / 5%/step]
*EGB
[0 to 1275 / P2a: 200, P2b: 130 / 5%/step]