Service Mode Table
5816 007
SSL Disable
5816 008
RCG Connect T/O
5816 009
RCG Write Timeout
5816 010
RCG Read Timeout
5816 011
Port 80
5816 021
Function Flag
5816 022
Install Status
Connect Mode (N/M)
This SP displays and selects the Cumin connection method.
5816 023
0: Internet connection
1: Dial-up connection
NotiTime ExpTime
5816 061
Proximity of the expiration of the certification.
HTTP Proxy use
5816 062
This SP setting determines if the proxy server is used when the machine
communicates with the service center.
G160/G161
CÓPIA NÃO CONTROLADA
0: Off (The remote service function is
disabled.)
1: On (The remote service function is
enabled.)
[0 to 1 / 0 / 1/step]
*CTL
0: On, 1: Off
Sets the timeout counter for the remote
*CTL
connection.
[1 to 90 / 10 / 1 second/step]
Sets the timeout counter for writing
*CTL
processing.
[0 to 100 / 60 / 1 second/step]
Sets the timeout counter for reading
*CTL
processing.
[0 to 100 / 60 / 1 second/step]
Enables or disables access to the SOAP
method via port 80.
*CTL
[0 to 1 / 0 / 1/step]
0: Disables, 1: Enables
[0 or 1 / 0 / -]
*CTL
0: Not registered, 1: Registered
This SP displays the Cumin installation
status.
*CTL
0: Basil not registered
1: Basil registered
2: Device registered
*CTL
*CTL
*CTL
5-106
CÓPIA NÃO CONTROLADA
SM