[Separa. : LE: HH] Separation Voltage: Correction for HH Humidity at the
Leading Edge
(Paper Type, Process Speed, [Color]) Paper Type -> Normal, Thin
Process Speed -> LS: Low speed, RS: Regular speed
2930
The value displayed on the LCD is different from these SP's values.
For example, "20%" on the LCD actually means 100%.
2930 001
Normal: RS: [K]
2930 002
Normal: RS: [FC]
2930 003
Normal: LS: [K]
2930 004
Normal: LS: [FC]
2930 005
Normal 2: RS: [K]
2930 006
Normal 2: RS: [FC]
2930 007
Normal 2: LS: [K]
2930 008
Normal 2: LS: [FC]
2930 009
Thin: RS: [K]
2930 010
Thin: RS: [FC]
2930 011
Thin: LS: [K]
2930 012
Thin: LS: [FC]
[T2:LL:SP1] Transfer Roller Current: Correction for Humidity, LL
Environment, Special paper1,
(Process Speed, [Color]) LS: Low Speed, RS: Regular Speed
2938
The value displayed on the LCD is different from these SP's values.
For example, "20%" on the LCD actually means 100%.
2938 001
RS [K]: 1st
2938 002
RS [K]: 2nd
2938 003
RS [FC]: 1st
2938 004
RS [FC]: 2nd
2938 005
LS [K]: 1st
2938 006
LS [K]: 2nd
SM
CÓPIA NÃO CONTROLADA
from these SP's values. For example, "20%"
on the LCD actually means 100%.
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
[0 to 400 / 200 / 5%/step]
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
[0 to 1275 / 80 / 5%/step]
*EGB
[0 to 1275 / 80 / 5%/step]
*EGB
[0 to 1275 / 90 / 5%/step]
*EGB
[0 to 1275 / P2a: 80, P2b: 95 / 5%/step]
*EGB
[0 to 1275 / P2a: 65, P2b: 100 / 5%/step]
*EGB
[0 to 1275 / 65 / 5%/step]
5-77
CÓPIA NÃO CONTROLADA
Service Mode Table