Ld Safety Switch - Ricoh G104 Service Manual

G104; g160; g161
Table of Contents

Advertisement

6.4.4 LD SAFETY SWITCH

A safety switch turns off when the front cover or the right door is opened. As a
result, a relay on the PSU cuts the power supply (+5V) to the four LD boards. (The
electric circuits run through the EGB and IOB.)
The LD safety switch system interrupts the laser beam circuit when the cover is
open.
Front and Upper Right Cover Switch
The front cover and the right cover are
mechanically connected to the actuator.
The actuator is mechanically connected to
the safety switch. When one of these
covers is opened or closed, the actuator
opens or closes the safety switch.
SM
CÓPIA NÃO CONTROLADA
+5VE2
PSU
6-29
CÓPIA NÃO CONTROLADA
LASER EXPOSURE
EGB
IOB
Door SW
LDB (C)
LD Control IC
LDB (M)
LD Control IC
LDB (Y)
LD Control IC
LDB (K)
LD Control IC
G105D901.WMF
G104