1916
[Nip Measure] Fusing Nip Width Measurement
1916 001
Nip Measure Exe.
Performs the nip width measurement.
1916 002
Prerotation Time
Adjusts the rotation time of the fusing unit rollers before the nip measurement.
[Environ. Adapt.] Fusing Idling: Environment Correction
The machine automatically adjusts the duration of fusing idling, depending on
room temperature measured by the temperature/humidity sensor
(Paper Type, Temperature Environment, Value of Temperature/ Rotation Time)
1917
Paper Type ->N1: Plain paper 1, N2: Plain paper 2, T1: Thick paper 1, T2: Thick
paper 2, SP: Special (see the Specifications table for details on these paper
weights)
Temperature Environment -> H: High temperature, L: Low temperature
Value of Temperature/ Time: Dec.: Decrease, Inc.: Increase
1917 003
H: Rotat. Time Dec.
1917 004
N1: H: Temp. Dec.
1917 005
N1: L: Temp. Inc.
1917 006
L: Rotat. Time Inc.
1917 007
H: Standard Temp.
1917 008
L: Standard Temp.
1917 009
L: Rotation Dec.
1917 010
N2: H: Temp. Dec.
1917 011
N2: L: Temp. Inc.
1917 012
TN: H: Temp. Dec.
1917 013
TN: L: Temp. Inc.
SM
CÓPIA NÃO CONTROLADA
[0 or 1 / 0 /-]
0: Not execute, 1: Execute
*EGB
[0 to 60 / 10 / 1 sec/step]
*EGB
Adjusts the rotation time decrease at high
temperature.
[-120 to 0 / 0 / 1 sec/step]
*EGB
Adjusts the temperature decrease for plain
paper 1 at high temperature.
[-50 to 0 / 0 / 1°C/step]
*EGB
Adjusts the temperature increase for plain
paper 1 at low temperature.
[0 to 30 / 7 / 1°C/step]
*EGB
Adjusts the rotation time increase at low
temperature.
[0 to 120 / 0 / 1 sec/step]
*EGB
Sets the threshold temperature detected as
high temperature.
[25 to 40 / 30 / 1°C/step]
*EGB
Sets the threshold temperature detected as
low temperature.
[-15 to 30 / 18 / 1°C/step]
*EGB
Adjusts the rotation time decrease at low
temperature.
[0 to 100 / 20 / 1 sec/step]
*EGB
Adjusts the temperature decrease for plain
paper 2 at high temperature.
[-50 to 0 / 0 / 1 sec/step]
*EGB
Adjusts the temperature increase for plain
paper 2 at low temperature.
[0 to 30 / 10 / 1°C/step]
*EGB
Adjusts the temperature decrease for thin
paper at high temperature.
[-50 to 0 / 0 / 1 sec/step]
*EGB
Adjusts the temperature increase for thin
paper at low temperature.
[0 to 30 / 7 / 1°C/step]
5-19