SERVICE MODE TABLE
3562
[Vk Display] ([Color])
3562 001
[K]
3562 002
[M]
3562 003
[C]
3562 004
[Y]
3573
[Vd Display] ([Color])
3573 001
[K]
3573 002
[M]
3573 003
[C]
3573 004
[Y]
3574
[Vl Display] ([Color])
3574 001
[K]
3574 002
[M]
3574 003
[C]
3574 004
[Y]
[Vb Display]
3575
(Process Speed,[Color]) RS: Regular speed, LS: Low speed
3575 001
RS: [K]
3575 002
RS: [M]
3575 003
RS: [C]
3575 004
RS: [Y]
3575 005
LS: [K]
3575 006
LS: [M]
3575 007
LS: [C]
3575 008
LS: [Y]
[Charge Bias] Charge Roller Bias
3576
(DC, Process Speed,[Color]) RS: Regular speed, LS: Low speed
3576 001
DC: RS: [K]
3576 002
DC: RS: [M]
3576 003
DC: RS: [C]
3576 004
DC: RS: [Y]
3576 005
DC: LS: [K]
3576 006
DC: LS: [M]
3576 007
DC: LS: [C]
3576 008
DC: LS: [Y]
[Charge Bias] Charge Roller Bias
3577
(AC, Process Speed,[Color]) RS: Regular speed, LS: Low speed
3577 001
AC: RS: [K]
3577 002
AC: RS: [M]
3577 003
AC: RS: [C]
3577 004
AC: RS: [Y]
G104
CÓPIA NÃO CONTROLADA
*EGB
Displays the current Vk value.
[-300 to 300 / 0 / 1 V/step]
*EGB
*EGB
*EGB
*EGB
Displays the current Vd value.
[0 to 1000 / 0 / 1 V/step]
*EGB
*EGB
*EGB
*EGB
Displays the current Vl value.
[0 to 1000 / 0 / 1 V/step]
*EGB
*EGB
*EGB
*EGB
Displays the current Vb value for each mode.
[0 to 800 / 350 / 1 V/step]
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
Displays the current charge roller DC bias of
the development unit for each mode.
*EGB
[0 to 999 / 585 / 1 V/step]
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
Displays the current charge roller AC bias of
the development unit for each mode.
*EGB
[0.0 to 3.0 / 1.9 / 0.001 kV/step]
*EGB
*EGB
5-54
CÓPIA NÃO CONTROLADA