SERVICE MODE TABLE
1917 014
TC1: H: Temp. Dec.
1917 015
TC1: L: Temp. Inc.
1917 016
TC2: H: Temp. Dec.
1917 017
TC2: L: Temp. Inc.
1917 018
OHP: H: Temp. Dec.
1917 019
OHP: L: Temp. Inc.
1917 020
SP: H: Temp. Dec.
1917 021
SP: L: Temp. Inc.
G104
CÓPIA NÃO CONTROLADA
*EGB
Adjusts the temperature decrease for thick
paper 1 at high temperature.
[-50 to 0 / 0 / 1 sec/step]
*EGB
Adjusts the temperature increase for thick
paper 1 at low temperature.
[0 to 30 / 7 / 1°C/step]
*EGB
Adjusts the temperature decrease for thick
paper 2 at high temperature.
[-50 to 0 / 0 / 1 sec/step]
*EGB
Adjusts the temperature increase for thick
paper 2 at low temperature.
[0 to 30 / 7 / 1°C/step]
*EGB
Adjusts the temperature decrease for OHP at
high temperature.
[-50 to 0 / 0 / 1 sec/step]
*EGB
Adjusts the temperature increase for OHP at
low temperature.
[0 to 30 / 7 / 1°C/step]
*EGB
Adjusts the temperature decrease for special
paper at high temperature.
[-50 to 0 / 0 / 1 sec/step]
*EGB
Adjusts the temperature increase for special
paper at low temperature.
[0 to 30 / 7 / 1°C/step]